V0802, 3.14.a
Parameter MP: Mute programmable per bend step 1/0
Range : 0-1
Default : 0
Units : -
Function
Enable or disable the mute parameter for the operator in the data edit mode.
Description
In the standard situation (OFF), the mute point for each bend is calculated from the mute
distance of the die. In some situations, it is desired that the operator can change the mute point
for a bend. When this parameter is switched ON, the mute point can be changed for each
individual bend of a program.
Press the key to select the required setting.