Parameter 31: Closing speed incr.
Range : 0.0 - 200.0
Default : 100.0
Units : Steps per 5ms.
Function
Y-axis closing acceleration
Description
Acceleration of the Y-axis during closing.
When the beam is in the upper dead point, it accelerates with this value when the closing
command becomes active (status = 2, see "service row") until the value "closing speed" is
reached.