Delem
V0802, 3.42
Parameter 42: Y-ref search speed
Range : 10.0 - 250.0
Default : 125.0
Units : mm/s
Function
Setting of the Y-axis speed during reference search.
Description
This is the speed with which the beam is controlled in the upward direction during the reference
search cycle.
When the reference search cycle of he Y-axis is started, the beam is controlled in the upward
direction with the speed which is programmed here. The sequence of the complete reference
cycle depends on the position of the beam:
if the beam was positioned below the reference point, the Y-axis will reach the reference
point and set the position;
if the beam was positioned above the reference point, the beam will also move upwards
with the programmed speed. When the beam reaches the mechanical upper dead point, the
control will detect after a short period that there is no movement and will stop the
movement. As soon as a closing command is generated, the beam is controlled downwards
with closing speed (parameter 30). The beam should now find reference.