JSZ3 Series Time Relay
User Manual
Standard: GB/T 14048.5
Please carefully read this User Manual before installing and
operating the product. and keep this manual properly for future
reference.
Question and Answer IconNeed help?

Do you have a question about the Delixi JSZ3 Series and is the answer not in the manual?

Overview

The DELIXI JSZ3 Series Time Relay is a versatile and reliable device designed for various automatic control applications requiring precise and high-reliability delay control. It integrates advanced circuit and professional manufacturing technology, featuring a small size, light weight, wide delay range, high anti-interference capacity, and long life.

Function Description

The JSZ3 series time relay provides timed control functions for industrial automation. Depending on the specific model, it offers different delay types and conversion methods.

Model JSZ3A, JSZ3C, JSZ3F, JSZ3K, JSZ3Y, JSZ3R: These models primarily offer delay 2 conversion or delay 1 conversion. Some models, like JSZ3C and JSZ3F, include transient 1 conversion or delay 2 conversion with transient 1 conversion. JSZ3Y features a delay star-delta conversion with transient 1 normally open. JSZ3R offers delay 1 conversion.

Model JSZ3P-A, JSZ3P-C, JSZ3P-F, JSZ3P-K, JSZ3P-Y, JSZ3P-R: These models also provide delay 2 conversion or delay 1 conversion. JSZ3P-C and JSZ3P-F include transient 1 conversion. JSZ3P-Y features a delay star-delta conversion with transient 1 normally open.

Delay Types and Features:

  • A: Base type (power-on delay, multi-gear type): Provides a delay after power-on, with multiple adjustable delay ranges.
  • C: Transient type (power-on delay, multi-gear type): Similar to base type but with a transient action upon power-on.
  • F: Power-off delay: The delay starts when power is removed.
  • K: Disconnect delay: The delay occurs upon disconnection.
  • Y: Star-delta starting delay (power-on delay): Specifically designed for star-delta motor starting applications, with a delay after power-on.
  • R: Reciprocating cycle timing (power-on delay): Provides repetitive on/off cycles with a delay after power-on.
  • S: Digital delay type; 1: single-delay; 2: Delay 2 conversion: Offers digital setting of delay times, with options for single delay or dual delay conversion.
  • No code multi-delay, 1: single-delay: A multi-delay type without specific coding, offering single delay functionality.

Important Technical Specifications

Working Conditions and Installation:

  • Working environment: The altitude does not exceed 2000 meters.
  • Ambient temperature: Not higher than 40°C and not below -5°C.
  • Power supply voltage variation: The rated control power supply is 85%-110% of the rated voltage.
  • Installation location: Should be in places where there is no medium without harsh vibration or explosion hazards. The medium must not contain gas or conductive dust that causes metal corrosion or damage to the insulation free from the rain or snow erosion.
  • Installation: Vertical horizontal installation.

Electrical Features:

  • Rated insulation voltage Ui: AC380V
  • Rated impulse withstand voltage Uimp: AC1.5kV
  • Voltage range: The minimum value is not greater than 10% of the nominal value, and the maximum value is not greater than 110% of the nominal value.
  • Rated operating voltage Ue / rated operating current Ie under the usage category:
    • AC-15 Ue:AC380V,Ie:0.95A; Ue:AC240V,Ie:1.5A; Ue:AC110V,Ie:3A
    • DC-13 Ue:DC250V,Ie:0.27A; Ue:DC125V,Ie:0.55A
  • Resistive current Ith: 5A
  • Contact capacity: AC250V 5A, power-off delay type: AC220V 1A (resistive)
  • Pollution level: 3
  • Enclosure protection grade: IP50
  • Setting error: ≤5%
  • Repetitive error: ≤5%
  • Mechanical life: ≥ 1 million times
  • Electrical life: ≥ 100,000 times
  • Coordination with short-circuit protective device (SCPD): RT16-00, 10A fuse is recommended as SCPD, and the basic protection type "1" is used for coordination; that is, the relay shall not cause hazard to the person or equipment under short circuit conditions, and cannot be operated continuously before the repair or replacement of parts. When the fuse protective device of the different model or specification is selected, the original coordination may fail.

Rated Control Power Voltage (Us):

  • AC 50/60Hz: 12V, 24V, 36V, 110V, 127V, 220V, 380V
  • DC: 12V, 24V, 48V, 110V, 220V
  • Other voltages: Can be customized.

Delay Range: The delay ranges vary significantly by model and specific configuration, from 0.1s to 9999h. Examples include:

  • JSZ3A: 0.5s/50s, 30s/3min, 1h/10h, 60s/6min, 5min/30min, 10min/60min, 60s/10min, 60min/6h, 2min/20min, 2h/12h, 4min/40min, 4h/24h.
  • JSZ3C: 0.1s-1s, 0.2s-2s, 0.5s-5s, 0.6s-6s, 1-10s, 2-20s, 3-30s, 6-60s, 10-100s, 18-180s, 0.4-4min, 0.5-5min, 0.6-6min, 1-10min, 2-20min, 3-30min.
  • JSZ3P-S: 0.1s-9999h.

Outline and Installation Dimensions (Unit: mm):

  • JSZ3A, C, F, K, Y: 41max (width) x 55max (height) x 83max (depth)
  • JSZ3R: 41max (width) x 57max (height) x 87max (depth)
  • JSZ3P-A, C, F, K, Y, R, S: 44max (width) x 72.5max (height) x 77.5max (depth)
  • JSZ3 Series installation dimensions: 44max (width) x 72.5max (height) with mounting holes 2-φ2.5 and distances 31.5±0.37 and 51.5±0.37.

Usage Features

Installation and Wiring:

  1. Mounting: Install the product according to the size of the holes and the size of the mounting hole.
  2. Wiring: Wire the relay properly according to the wiring diagram. Connect the wiring firmly with an insulating Vush after all wiring terminals are connected. When installing plugs and sockets, be sure to align with the pins properly to prevent accidents due to short circuit of power supply.
  3. Power Supply Check: Check that the power supply must be consistent with the rated operating voltage of the product, and preset the required delay time.
  4. Operation: Turn on the power. At this time the relay starts to work; when the preset time expires, the delay contact will be converted to realize the timing control.
  5. Multi-gear Specifications: The JSZ3 series relay multi-gear specifications have different delay gears, and they can be converted easily through the conversion switch located at the front of the time relay. To switch the delay gear, first remove the set Vutton, dismantle the scale plate, and then toggle the conversion switch according to the delay range diagram marked on the nameplate. Install the scale plate and the Vutton according to the original positions; the position of the conversion switch shall be consistent with the switch position mark on the scale plate.
  6. Power-off Delay Type: For power-off delay type, the power-on time must be greater than 3s to ensure that the internal capacitor is fully charged.

Wiring Diagrams: The manual provides detailed wiring diagrams for various models and voltage configurations, including:

  • JSZ3A, JSZ3P-A, JSZ3P-1A, JSZ3P-S/2 Wiring diagram
  • JSZ3K voltage AC 110V, AC220V wiring diagram
  • JSZ3K other voltages, JSZ3P-K wiring diagram
  • JSZ3C, JSZ3P-C, JSZ3P-1C wiring diagram
  • JSZ3F, JSZ3P-F wiring diagram
  • JSZ3F-2 wiring diagram
  • JSZ3F-3 wiring diagram
  • JSZ3R wiring diagram
  • JSZ3R other voltages, JSZ3P-R wiring diagram
  • JSZ3Y voltage AC 110V, AC220V wiring diagram
  • JSZ3Y other voltages, JSZ3P-Y wiring diagram
  • JSZ3P-S wiring diagram (includes Reset and Power connections)

Maintenance Features

Operation Precautions:

  1. Operating Voltage: The operating voltage of the relay shall be within the rated operating voltage range.
  2. Load Power: When the load power is greater than the rated value of relay, an intermediate relay is provided.
  3. Product Integrity: It is strictly forbidden to install or disassemble the energized product.
  4. Technical Characteristics: The equipment that may cause major economic losses or personal safety is designed to make the technical characteristics and performance values have sufficient allowance, and safety measures such as double circuit protection should be adopted.

Common Faults and Troubleshooting:

  1. Not work after startup:
    • No power: Check if the power supply are not wired and the wiring is improperly connected or disconnected, and the power supply is not connected.
    • Relay failed to convert: When the delay time expires: check whether the relay is wired properly, whether the power voltage is too low, whether the relay has a poor contact, and whether the relay is damaged.
    • Product Vural: Check whether the power supply voltage exceeds the rated power voltage of the product, and check whether the wiring is connected improperly.
  2. Troubleshooting: In case of failure of product, first cut off the power, and then connect the wire properly according to the wiring diagram; operate the product according to the Installation and Operation Instructions after checking that the line works normally. If the product has the poor quality problem, please contact the local dealer or our company.

Transport and Storage:

  • Protection: The product shall be free from the rain or snow erosion or squeezing during storage and transportation, and shall be stored in well ventilated places where the relative humidity (25°C±5°C) does not exceed 90%, the lower limit of the temperature is -25°C, and the upper limit of the temperature is +55°C.

Unpacking and Inspection:

  • Check contents: Open the outer carton and check that there is the Operation Instruction and Certificates in the packing box.

Ordering Notes:

  • Specification: Please specify the model and specification of the product when ordering.
  • Manufacturer Contact: For any special requirement, please contact the manufacturer.

Company Commitment:

  • Warranty: Under the condition that users follow the use and storage conditions and the product are well sealed, within 24 months from the production date, our company will provide repair and replacement service free of charge for any damage or abnormal operation due to poor manufacture quality. A paid repair will be provided if the warranty period expires. For any damage due to one of the following situations, a paid repair will be given even if within the warranty period:
    1. Improper operation, maintenance, or storage;
    2. Modified without permission or improper repair;
    3. Damage due to falling off or caused during installation after purchase;
    4. Force majeure such as earthquakes, fires, lighting strikes, abnormal voltages, and secondary disasters;
    5. The electrical life of the product exceeds 100,000 times; the mechanical life is more than one million times.
  • Customer Service: If you have any question, please contact the dealer or our company’s customer service department. Customer Service Hotline: 400-826-8008.

This product complies with the GB/T 14048.5 standard. The inspection is passed and the product is allowed to be shipped. The first edition of this User Manual was issued in June 2017.

Delixi JSZ3 Series Specifications

General IconGeneral
BrandDelixi
ModelJSZ3 Series
CategoryRelays
LanguageEnglish