EasyManua.ls Logo

Dell DR4100 - Page 111

Dell DR4100
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Code Message Information
MEM8000
Message Correctable memory error logging disabled for a memory device at
location <
location
>.
Details Errors are being corrected but no longer logged.
Action Review system logs for memory exceptions. Reinstall memory at
location <
location
>.
PCI1302
Message A bus time-out was detected on a component at bus <
bus
>
device<
device
> function <
func
>.
Details System performance may be degraded. The device has failed to
respond to a transaction.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1304
Message An I/O channel check error was detected.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1308
Message A PCI parity error was detected on a component at bus
<
bus
>device<
device
>function <
func
>.
Details System performance may be degraded, PCI device may fail to
operate, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1320
Message A bus fatal error was detected on a component at bus
<
bus
>device<
device
>function <
func
>.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1342
Message A bus time-out was detected on a component at slot <
number
>.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1348
Message A PCI parity error was detected on a component at slot <
number
>.
111

Table of Contents

Other manuals for Dell DR4100

Related product manuals