4
14. Main dimensions / weight:
Monitor
Packed Monitor
Width: 410mm 515mm
Height: 402mm 464mm
Depth: 420mm 570mm
Weight: 15.5kg 17.5kg
15. Press the “MENU”funtion and don’t release it,then press power swith on,the monitor will enter
the burn-in mode if it is no signal input.
16. Regulations/Safety:
- EN 60950 + EK1-ITB: GS-mark
- UL60950
- cUL CSA C22.2 No.60950
- VDE 0860 (implosion protection)
- CE-mark
- CB-certificate and test report according to IEC60950
The model is designed to reach following approvals:
- EN 55022 class B and EN 55024
- EN 61000-3-2& EN61000-3-3
Test procedures Standards Requirements frequency
range
Remarks
Conducted power-line
emission
EN 55022 Class B
FCC Part 15, Subq.B
150 kHz ~ 30 MHz
450 kHz ~ 30 MHz
Radiation emission
EN 55022 Class B
FCC Part 15, Subq.B
30 MHz ~ 1 GHz
30 MHz ~ 1 GHz
30 MHz ~ 2 GHz
if clock > 108 MHz
Electrostatic (ESD)
EN 55024 IEC61000-
4-2
- no functional
disturbance:
8 kV air discharge
Immunity to RF field
strength
EN 55024 IEC61000-
4-3
80 MHz ~ 1000 MHz
3V/m
modulation
Electrical fast transient EN 55024 IEC61000-
4-4
- no functional
disturbance:
1 kV power cord
0.5kV signal cable
SURGE
EN 55024
IEC61000-4-5
CS
EN 55024
IEC61000-4-6