Stacking Dell PowerConnect Switches: 8132, 8132F, 8164, 8164F
18
After login, the first screen to appear is the Home screen, which shows the current stacking member
number. Before stacking, the single member has the Stack number of 1 (one).
The example above shows a Dell PowerConnect 8132F with a QSFP+ two-port expansion module
installed in Slot 1. The two 40G QSFP+ ports are interfaces F01/1/1 and F01/1/2. We will use these
two interfaces for stacking in the example below.
Click System > Stack Management > Stack Port Summary to bring up the next page used to select the
ports for stacking. For this example ports F01/1/1 and F01/1/2 are used.