20 Information Update
E2110 MBE DIMM # & # One of the two
indicated DIMMs
has had a memory
multi-bit error
(MBE).
See
"Troubleshooting
System Memory"
in the Hardware
Owner’s Manual.
E2111 SBE Log
Disable DIMM #
The system BIOS
has disabled
memory single-bit
error (SBE) logging,
and does not
resume logging
further SBEs until
the system is
restarted. "#"
represents the
DIMM implicated
by the BIOS.
See
"Troubleshooting
System Memory"
in the Hardware
Owner’s Manual.
E2112 Mem Spare
DIMM #
The system BIOS
has spared the
memory because it
has determined that
the memory had too
many errors. "# &
#" represents the
DIMM pair
implicated by
the BIOS.
See
"Troubleshooting
System Memory"
in the Hardware
Owner’s Manual.
I1915 Video Off
(LCD lights with
a blue or amber
background.)
The video has been
turned off by the
RAC remote user.
Information only.
I1916 Video Off
in ##
(LCD lights with
a blue or amber
background.)
The video was
turned off in xx
seconds by the RAC
remote user.
Information only.
Table 1-2. LCD Status Messages (continued)
Code Text Causes Corrective Actions