Information Update 15
Table 1-2. LCD Status Messages
Code Text Causes Corrective Actions
N/A SYSTEM NAME
A 62-character string that
can be defined by the user
in the System Setup
program.
The SYSTEM NAME
displays under the
following conditions:
The system
is powered on.
The power is off
and active errors
are displayed.
This message is for
information only.
You can change the
system ID and name
in the System Setup
program. See “Using the
System Setup Program”
in the Hardware Owner’s
Manual.
E1000 FAILSAFE,
Call Support
Check the system event
log for critical failure
events.
See “Getting Help” in
the Hardware Owner’s
Manual.
E1118 CPU Temp
Interface
The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan
speed to maximum
as a precautionary
measure.
Turn off power to the
system and restart the
system. If the problem
persists, see “Getting
Help” in the Hardware
Owner’s Manual.
E1211 ROMB Batt
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See the “RAID
Battery” and see
Troubleshooting System
Cooling Problems” in
the Hardware Owner’s
Manual.
E1625 PS AC Current
Power source is out
of acceptable range.
Check the AC power
source.

Table of Contents