18 Information Update
NOTE: Each diagnostic LCD message is assigned a priority. The highest priority
messages supersede any group of messages with a lower priority.
E2111 SBE Log
Disable DIMM #
The system BIOS has
disabled memory single-
bit error (SBE) logging,
and does not resume
logging further SBEs until
the system is restarted.
“#” represents the DIMM
implicated by the BIOS.
See “Troubleshooting
System Memory”
in the Hardware Owner’s
Manual.
E2112 Mem Spare
DIMM #
The system BIOS has
spared the memory
because it has determined
that the memory had too
many errors. “# & #”
represents the DIMM pair
implicated by the BIOS.
See “Troubleshooting
System Memory”
in the Hardware Owner’s
Manual.
I1915 Video Off
(LCD lights with
a blue or amber
background.)
The video is turned off by
the RAC remote user.
Information only.
I1916 Video Off
in ##
(LCD lights with
a blue or amber
background.)
The video is turned off in
xx seconds by the RAC
remote user.
Information only.
Table 1-2. LCD Status Messages (continued)