Dell PowerVault MD32xxi Configuration Guide for VMware ESX4.1 Server Software
Page 32
esxcfg-vmknic a i 10.10.5.175 n 255.255.255.0 m 9000 iSCSI3
esxcfg-vswitch A iSCSI4 vSwitch2
esxcfg-vmknic a i 10.10.5.176 n 255.255.255.0 m 9000 iSCSI4
esxcfg-vswitch A iSCSI5 vSwitch2
esxcfg-vmknic a i 10.10.5.177 n 255.255.255.0 m 9000 iSCSI5
esxcfg-vswitch A iSCSI6 vSwitch2
esxcfg-vmknic a i 10.10.5.178 n 255.255.255.0 m 9000 iSCSI6
To create less VMkernel Ports just skip iSCSI5 and iSCSI6 for example.
To verify the configuration enter the following command:
esxcfg-vswitch l
This will show the VMkernel ports that are assigned to the vSwitch. To verify the IP addresses enter the
following command:
esxcfg-vmknic l
You can also verify the IP Addresses via the vCenter GUI. Navigate to Configuration ->
Networking.