DELL™ PRECISION™ T3600 TECHNICAL GUIDEBOOK
15
SYSTEM LEVEL ENVIRONMENTAL AND OPERATING CONDITIONS
Temperature
Operating 10° to 35° C (50° to 95° F)
Non-Operating (Storage) -40° to 60° C (-40° to 140° F)
Relative Humidity 20% to 80% (non-condensing)
Maximum vibration
Operating 5 to 350 Hz at 0.0002 G²/Hz
Non-Operating 5 to 500 Hz at 0.001 to 0.01 G²/Hz
Maximum Shock
Operating
40 G +/- 5% with pulse duration of 2 msec +/-
10% (equivalent to 51 cm/sec [20 in/sec])
Non-Operating
105 G +/- 5% with pulse duration of 2 msec +/-
10% (equivalent to 127 cm/sec [50 in/sec])
Maximum Altitude
Operating –15.2 to 3048 m (–50 to 10,000 ft)
Non-Operating –15.2 to 10,668 m (–50 to 35,000 ft)
POWER
NOTE: These form factors utilize a more ecient Active Power Factor Correction (APFC) power supply. Dell recommends only Universal Power
Supplies (UPS) based on Sine Wave output for APFC PSUs, not an approximation of a Sine Wave, Square Wave, or quasi-Square Wave. If you
have questions, please contact the manufacture to conrm the output type.
Entry Upsell
Power Supply Wattage 425W 635W
AC input Voltage
Range
100 - 240 Vac 100 - 240 Vac
AC input current (low
ac range/high AC
range)
6.0A / 3.0A 9.0A / 4.5A
AC input Frequency 47 Hz / 63Hz 47 Hz / 63Hz
AC holdup time (80%
load)
16 MSEC 16 MSEC
Average Eciency
(Energy Star 5.0 Com-
pliant)
87 – 90 – 87% @ 20 – 50 – 100% load 87 – 90 – 87% @ 20 – 50 – 100% load