DELL™ PRECISION™ T5600 TECHNICAL GUIDEBOOK
15
SYSTEM LEVEL ENVIRONMENTAL AND OPERATING CONDITIONS
Temperature
Operating 10° to 35° C (50° to 95° F)
Non-Operating (Storage) -40° to 60° C (-40° to 140° F)
Relative Humidity 20% to 80% (non-condensing)
Maximum vibration
Operating 5 to 350 Hz at 0.0002 G²/Hz
Non-Operating 5 to 500 Hz at 0.001 to 0.01 G²/Hz
Maximum Shock
Operating
40 G +/- 5% with pulse duration of 2 msec +/-
10% (equivalent to 51 cm/sec [20 in/sec])
Non-Operating
105 G +/- 5% with pulse duration of 2 msec +/-
10% (equivalent to 127 cm/sec [50 in/sec])
Maximum Altitude
Operating –15.2 to 3048 m (–50 to 10,000 ft)
Non-Operating –15.2 to 10,668 m (–50 to 35,000 ft)
POWER
NOTE: The T5600 utilizes an Active Power Factor Correction (APFC) power supply to enhance eciency. Dell recommends only Universal
Power Supplies (UPS) based on Sine Wave output for APFC power supplies, not an approximation of a Sine Wave, Square Wave, or quasi-Square
Wave. If you have questions, please contact the manufacture to conrm the output type.
Standard Optional
Power Supply Wattage 635W 825W
AC input Voltage
Range
100 - 240 Vac 100 - 240 Vac
AC input current (low
ac range/high AC
range)
9.0A / 4.5A 12.0 A / 6.0 A
AC input Frequency 47 Hz / 63Hz 47 Hz / 63Hz
AC holdup time (80%
load)
16 MSEC 16 MSEC
Average Eciency
(Energy Star 5.2 Com-
pliant)
87 – 90 – 87% @ 20 – 50 – 100% load 87 – 90 – 87% @ 20 – 50 – 100% load