DELL™ PRECISION™ T7600 TECHNICAL GUIDEBOOK
15
SYSTEM LEVEL ENVIRONMENTAL AND OPERATING CONDITIONS
Temperature
Operating 10° to 35° C (50° to 95° F)
Non-Operating (Storage) -40° to 60° C (-40° to 140° F)
Relative Humidity 20% to 80% (non-condensing)
Maximum vibration
Operating 5 to 350 Hz at 0.0002 G²/Hz
Non-Operating 5 to 500 Hz at 0.001 to 0.01 G²/Hz
Maximum Shock
Operating
40 G +/- 5% with pulse duration of 2 msec +/-
10% (equivalent to 51 cm/sec [20 in/sec])
Non-Operating
105 G +/- 5% with pulse duration of 2 msec +/-
10% (equivalent to 127 cm/sec [50 in/sec])
Maximum Altitude
Operating –15.2 to 3048 m (–50 to 10,000 ft)
Non-Operating –15.2 to 10,668 m (–50 to 35,000 ft)
POWER
NOTE: The T7600 utilizes an Active Power Factor Correction (APFC) power supply to enhance eciency. Dell recommends only Universal
Power Supplies (UPS) based on Sine Wave output for APFC power supplies, not an approximation of a Sine Wave, Square Wave, or quasi-Square
Specications
Power Supply Wattage
1300W (for AC input voltages of 181—240 Vac)
1100W (for AC input voltages of 108—180 Vac)
1000W (for AC input voltages of 100—107 Vac)
AC input Voltage Range 100 - 240 Vac
AC input current (low ac range/high AC range) 14.0 A / 7.0 A
AC input Frequency 47 Hz / 63Hz
AC holdup time (80% load) 16 MSEC
Average Eciency (Energy Star 5.2 Compliant) 87 – 90 – 87% @ 20 – 50 – 100% load
DC parameters
+12.0v output 12VABCDEFGHIJ ; 18.0A
+5.0v auxiliary output 4.0A
-12.0v output 0.5A
Max total power 1300W
BTUs/h (based on PSU max wattage) 4113.0 BTU
Power Supply Fan 60*25mm (x2)
Compliance:
1watt requirement Yes
Climate Savers / 80Plus Compliant Yes
FEMP (CECP) Standby Power Compliant Yes