TROUBLESHOOTING
SINGLE SPLIT
12 English 11/2002
The appliance doesn't work
• Are the protection devices or fuses faulty?
•
Have the connections come loose or the cable unplugged?
• At times operation is stopped to protect the appliance.
• Is the voltage above 244V or below 206V?
• Is the TIMER-ON functions active?
Insufficient cold or hot air produced
• Is the temperature suitably set?
•
Are the outlets and inlets of the air-conditioner blocked?
• Is the air filter dirty?
• Is the fan speed set to the minimum?
• Are there other sources of heat in the room?
The appliance does not respond to
• Is the remote control near the indoor unit?
• Are the batteries in the remote control flat?
• Are there obstacles between the remote control and
the signal receiver on the indoor unit?
Immediately switch off the air-conditioner and
disconnect the power supply in the event of:
•
Strange noises during operation.
• Faulty fuses or switches.
• Sprays of water or objects inside the appliance.
• Hot cables or plugs.
• Very strong smell coming from the appliance.
Strange noises can be heard
• This noise is produced by the expansion or contrac-
tion of the front panel due to the thermal variations,
and does not indicate a problem.
Sprays of atomised water from
• This occurs when the air in the room cools down very
quickly,for example in “COOLING” or “DEHUMIDIFI-
CATION” mode.
The appliance doesn't work
• Once switched off the air-conditioner cannot be started
for around 3 minutes
FAULT POSSIBLE CAUSE
Strange smell
• This smell may come from other sources, such as fur-
niture or the like.
Sound of running water
• This derives from the flow of refrigerant in the air-con-
ditioner,and is not a fault.
U I A