INTRODUCTION
This is a conditioner of the air-to-air type com-
posed of two units: one internal (which operates
inside the room) and the other external (to be
installed outside). These two units are joined
together by a sheathing (of about 3 m.) containing
the refrigerant pipes, electrical power cables and
condensation-discharge tube.
TECHNICAL FEATURES
Power supply
voltage See the features plate
Maximum absorbed power “
Cooling capacity* “
Max. air flow rate 560 m
3
/h
Flexible tube length 3 m
Sheathing section 20 x 44 mm
Dimensions: indoor unit
• length 560 mm
• height 735 mm
• depth 355 mm
• weight 44 kg
Dimensions: outdoor unit
• length 570 mm
• height 480 mm
• depth 260 mm
• weight 18 kg
* Standard conditioning:
Inside temperature 27°C
relative humidity: 47%
Outside temperature 35°C
relative humidity: 41%
Carefully read this instructions
booklet before installing or
using this appliance.
Only by doing so will you have
the best results and enjoy the
greatest safety when using the
appliance. Please pay particular
attention to the warnings on
page 28.
OPERATIONAL AIR-
CONDITIONING LIMITS
Room temperature 21 ÷ 32°C
Outside temperature 21 ÷ 43°C