19
ENGLISH
Warnings
This appliance is designed for home air conditioning and must not be used for other purposes.
It is dangerous to modify or alter the characteristics of the appliance in any way.
•The appliance must be installed in conformity with legislation in force in the country concerned.
If the appliance requires repair, contact a Service Centre authorised by the manufacturer only.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
This air conditioning unit must be used by adults only. Never allow children to play with the applian-
ce.
This appliance is designed for home air conditioning and must not be used for other purposes.
Do not allow children to play with the appliance.
•The appliance must be connected to an efficient earth system.
Have your electrical circuit checked by a qualified electrician.
Do not use extension cables.
Before cleaning or maintenance operations, always unplug the appliance from the mains socket.
Do not move the appliance by pulling the power cable.
Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.
Do not rest heavy or hot objects on top of the appliance.
•Clean the anti-microbial filters at least once a week.
•Avoid using heating appliances near the air conditioning unit.
Always transport the appliance upright or resting on one side.
•Use the appliance as described in this instruction manual only.
•As with any electrical appliance, while the instructions aim to cover as many eventualities as possible,
caution and common sense should be used when operating and installing this air conditioning unit.
•At the end of its working life, take the appliance to a special collection centre.
The materials used for packaging can be recycled. You are therefore recommended to dispose of
them in special differentiated waste collection containers.
When putting the appliance away, do not cover with plastic bags.
The refrigerant gas R407c conforms to EC regulations on the environment.
•Avoid perforating the refrigerant circuit of the appliance.
Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised
containers (e.g. aerosol cans).
DESCRIPTION
1
air outlet grille
2 control panel
3 castors
4 handles
5 evaporator air intake grille
6 air exhaust hose housing
7 condenser air intake grille
8 drain hose cover
9 power cable
10 flange cap
11 air exhaust hose
12 window outlet
13 suckers
14 castor locks
15 remote control unit (model L30/L40only)
Question and Answer IconNeed help?

Do you have a question about the DeLonghi Pinguino PAC L10 and is the answer not in the manual?

DeLonghi Pinguino PAC L10 Specifications

Operating Environment IconOperating Environment
temperature of the air-conditioned room21 - 35°C
temperature of the air-conditioned room (Mod. L20H)max. 25°C
Weight and Dimensions IconWeight and Dimensions
width505 mm
height825 mm
depth440 mm
weight34 kg

Summary

General Safety Warnings

Intended Use and Modifications

Appliance must be used only for home air conditioning and not modified.

Installation, Repair, and Electrical Safety

Proper installation, authorized repair, and safe electrical connections are mandatory.

Usage Restrictions and Handling

Adult supervision required; unplug before maintenance and avoid pulling by the power cable.

Environmental and Disposal Guidelines

Adhere to placement, cleaning, transport, and disposal guidelines for safety and environment.

Product Overview and Functionality

Air Conditioning Process

Explains how the appliance removes heat and moisture from room air.

Model Differences

Details cooling differences between Pinguino and SuperPinguino models.

Fan-Only Mode

All models can be used in fan-only mode.

Preparation for Use

Electrical Connection Checks

Verify power supply, socket adequacy, and earthing before plugging in.

Air Conditioning Without Installation

Steps for setting up air conditioning without permanent installation, using window kit.

Air Conditioning With Installation

Procedure for semi-permanent installation through a wall or window pane.

Control Panel Overview (L10/L15/L20H)

Control Panel Description

Details the functions of each button and indicator light on the control panel.

Operating the Unit (L10/L15/L20H)

Turning the Appliance On

Instructions for powering on the unit and selecting modes.

Air-Conditioning Mode

Guide for using the cooling function, setting temperature and fan speed.

Fan Mode Operation

Details on adjusting fan speed and its effects.

Heating Mode Operation

Instructions for heating mode (L20H only) and automatic fan speed.

Setting the Timer

Programming delayed start-up and shut down for optimized operation.

Self-Diagnosis and Error Codes (L10/L15/L20H)

Error Code Explanations

Lists error codes (LE, PF, FE) and their meanings and recommended actions.

Control Panel and Remote (L30/L40)

Control Panel Description

Identifies indicator lights and buttons on the main control panel.

Remote Control Usage

Guidance on correct handling, aiming, and battery replacement for the remote.

Operating the Unit (L30/L40)

Turning the Appliance On

Instructions for powering on and selecting operational modes.

Air-Conditioning Mode

Guide to cooling function, temperature, and fan speed settings.

Fan Mode Operation

Details on adjusting fan speed in fan-only mode.

Setting the Timer

Programming delayed shutdown for optimized operation.

Programming Delayed Start-up

Setting the appliance to turn on automatically at a future time.

Self-Diagnosis and Faults

Identifies self-diagnosis indicators and actions for tank full or probe issues.

Tips for Optimal Use

Room Preparation

Recommendations for closing windows/doors and managing sunlight.

Appliance Placement and Obstructions

Avoid resting objects, obstructing grilles, and ensure no heat sources are nearby.

Usage Environment

Avoid very damp rooms and outdoor use; ensure unit is on a level floor.

Cleaning and Maintenance

Cleaning the Cabinet

Instructions for cleaning the appliance exterior with a damp cloth.

Cleaning the Air Filters

Procedure for removing, cleaning, and replacing air filters for efficiency.

Start of Season Checks

Ensure power cable, plug, and earth system are undamaged and functional.

End of Season Operations

Steps for draining water, replacing caps, and cleaning filters before storage.

Troubleshooting Common Issues

Unit Does Not Start

Addresses no electricity, power connection, or tripped safety device.

Unit Works Briefly or Does Not Cool

Troubleshoots exhaust hose issues, open windows, heat sources, and clogged filters.

Particular Odour or Delayed Operation

Addresses clogged air filters and safety device reset delays.

Display Errors (L10/L15/L20H)

Explains display codes like LE/PF/Ft and U-tank alarm light.

Guarantee and Technical Specifications

Guarantee and Technical Assistance

Conditions for guarantee and technical assistance are on the supplied certificate.

Limit Conditions

Specifies temperature limits for air-conditioned rooms.

Technical Specification Details

Lists power supply, refrigerant, cooling capacity, and appliance dimensions/weight.

Refrigerant Handling and Disposal

Refrigerant transport, filling, and disposal must be done by authorized service centers.