EasyManua.ls Logo

Delsys Trigno Avanti User Manual

Delsys Trigno Avanti
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Trigno
®
Wireless
Biofeedback System
__
Avanti Analog Input
Adapter
User’s Guide
Copyright © 2019 by Delsys Incorporated
MAN-021-2-0
MP1289A
August 2019
No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval
system, or translated into any language in any form by any means without the written
permission of Delsys Inc.
Download EMGworks® at
www.delsys.com/emgworks
Question and Answer IconNeed help?

Do you have a question about the Delsys Trigno Avanti and is the answer not in the manual?

Delsys Trigno Avanti Specifications

General IconGeneral
Bandwidth (EMG)20-450 Hz
Magnetometer Range±8 Gauss
Input Range (EMG)±11 mV
Battery LifeUp to 8 hours
CommunicationBluetooth
EMG Noise< 1 µV RMS
Channels16
Sampling Rate2000 Hz
Resolution16 bit
Weight14 g
Data StorageOn board
CompatibilityWindows and macOS
TypeWireless EMG and IMU sensor system

Summary

Important Information

Intended Use

Describes the intended purpose of the Trigno Wireless Biofeedback System for researchers and clinicians.

Contraindications

Lists situations where the system should not be used, focusing on implants and skin conditions.

Technical Service and Support

Provides contact information for assistance and website resources for the product.

Warnings and Precautions

Device Information

Trigno System Overview

Trigno Analog Adapter Features

Details the key features and capabilities of the Trigno Analog Input Adapter.

Robust +/-5V Input Signal

Industry Standard Connectors

Pushbutton Event Marker

Dual Mode BLE-Base Communication

Wireless Communication

Data Synchronization

Rechargeable Battery

Sealed Enclosure

Internal Magnetic Switch

Sensor LED Feedback States

LED State Descriptions

Getting Started with the Analog Input Adapter

Configuring the Trigno Analog Input Adapter

Guides on how to configure the analog input adapter settings within the system.

Using the Analog Outputs (if Equipped)

Explains how to utilize the analog output signals from the Trigno System.

Analog Input Adapter Connections

Single Channel BNC Connection (DC-X06)

Quad Channel BNC Connection (DC-X07)

Biodex Isokinetic Device Connection (DC-X05)

Event Marker Button (DC-X08)

Maintenance and Care

Trigno Sensors

Provides guidelines for handling, cleaning, and maintaining Trigno sensors.

Specifications

Physical Specifications

Lists the physical dimensions, cable length, mass, and temperature range of the sensor.

Electrical Specifications

Details the RF band, input ranges, bandwidths, and delays of the system.

Analog Input Measurement Data Modes

Related product manuals