Electrical specifications
Item Specifications
Power supply to
device in IO-Link
mode or SIO (DI)
mode
Rated voltage
24 VDC (20.4 VDC~ 28.8 VDC) (9-15%~+20%)
Maximum load
current
0.2A/port
Short-circuit
protection
Yes
Digital inputs in
SIO (DI) mode
Internal I/O
common
NPN, PNP
Input voltage /
current
24 VDC, 5 mA
ON voltage
>15 VDC
OFF voltage
<5 VDC
Filter time
0 65 ms (0: no filter)
Digital outputs in
SIO (DO) mode
Internal I/O
common
NPN, PNP
Output voltage /
current
24 VDC (20.4 VDC~ 28.8 VDC), 0.1A/port
Short-circuit
protection
Yes
Leakage current
<0.1 mA
Residual
voltage
<1.5 VDC
Digital inputs for
pin 2 in IO-Link
mode
Internal I/O
common
NPN, PNP
Input voltage /
current
24 VDC, 2 mA
ON voltage
>15 VDC
OFF voltage
<5 VDC
Filter time
0 65 ms (0: no filter)
Electronical isolation
500 VAC
Power consumption
0.8 W
Weight
133g
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AS132P-A and is the answer not in the manual?

Delta AS132P-A Specifications

General IconGeneral
BrandDelta
ModelAS132P-A
CategoryNetwork Hardware
LanguageEnglish

Related product manuals