AS200 Series: Electrical specifications for the outputs
Model
AS228R-A
AS228T-A
AS228P-A
Number of outputs
AS228 Series: 12 outputs (Y0.0-Y0.11)
AS218 Series 6 outputs (Y0.0-Y0.5)
Removable spring-type terminal blocks
Output form
Relay Transistor-T (sinking)
Transistor-P
Max. inrush current
N/A
Transistor-T (sinking): 0.8 A
Transistor-P (sourcing): 7.5 A
ed condition: Ta = 25
0
C, V
DS
= 30VDC and
pulse duration = 1ms)
Maximum
load
Resistance
AS218
2A/output, 6A/COM 0.5A/output, 1.5A/COM
0.5A/output,
2
Bulb
20W (24 VDC)
N/A N/A
Maximum
output
frequency
1Hz 200kHz 200kHz
0.5Hz N/A N/A
Bulb
1Hz N/A N/A
Maximum
Response
OFF→ON
10 μs
2.5 μs
2.5 μs
ON→OFF
Analog output conversion
1
3 ms / channel (for AS218 PLC CPU)
AS218 Series: -10V~10V (voltage mode) or 0mA~20mA (currentmode)
Electrical output isolaiton
Analog output isolation
When there is isolation between alaog and digital electricals and there is
no isolation among analog channels.
Isolation between analog electrical and gronunding: 500 VAC
Isolation between analog and digital electrical: 500 VAC
*1: Analog output data updates automatically in every PLC program scan.
*2: Life cycle curve: The lifetime of a relay terminal varies with the working voltage, the load type (the power
factor cosψ, the time constant t(L/R)), and the current passing through the terminal. The relation is shown in
the life cycle curve below.
Contact Current(A)
20
0.5
0.1
0.2
30
50
0.3 0.7
1 2
200
300
500
100
1000
2000
3000
Operation(X10 )
3
120VAC Resistive
30VDC Inductive(t=7ms)
240VAC Inductive(cos 0.4)
ψ
=
120VAC Inductive(cos =0.4)
ψ
30VDC
Inductive
(t=40ms)