(5) Dimensions
DOP-B03S210
129(5.08")
103(4.06")
+1.0
118.8
0
(4.68" )
+1.0
92.8
0
(3.65" )
T
29.5(1.16")
91(3.58")
Note:
T=1.6mm(0.063")~6mm(0.24")
+0.04"
0
+0.04"
0
(6) Specifications
MODEL
DOP-B03S210
LCD MODULE
Display
Type
4.3" TFT LCD (65536 colors )
Resolution
480 x 272 pixels
Backlight
LED Back Light (less than 20,000 hours half-life at 25
o
C)
(Note 1)
Display
Size
95.04 x 53.856mm
Operation
System
Delta Real Time OS
MCU 32-bit RISC Micro-controller
NOR Flash
ROM
Flash ROM 8 MB
(OS System: 2MB / User Application: 6MB)
SDRAM
64Mbytes
Backup
Memory
N/A
Buzzer
Multi-Tone Frequency (2K ~ 4K Hz) / 85dB
USB 1 USB Slave Ver 2.0
Serial
COM
Port
COM1
RS-232(supports hardware flow control)RS-422RS-485
Cooling
Method
Natural air circulation
Safety
Approval
CE / UL
(Note 3)
Waterproof
Degree
IP65 / NEMA4
(Note 3)
Operation
Voltage
(Note2)
DC +24V (-10% ~ +15%) (please use isolated power supply)
Voltage
Endurance
AC500V for 1 minute (between charging (DC24V terminal)
and FG terminals)
Power
Consumption
(Note 2)
1.7W
Backup Battery N/A
Backup Battery
Life
N/A
Operation
Temperature
0oC ~ 50oC
Storage
Temperature
-20oC ~ +60oC
Ambient
Humidity
10% ~ 90% RH [0 ~ 40
o
C], 10% ~ 55% RH [41 ~ 50
o
C], Pollution Degree 2
Vibration
IEC 61131-2 compliant 5Hzf8.3Hz = Continuous: 3.5mm, 8.3Hzf
150Hz = Continuous: 1.0g
Shock
IEC 60068-2-27 compliant 15g peak for 11 ms duration, X, Y, Z directions
for 6 times
Dimensions
(W) x (H) x (D)
mm
129 x103 x 39
Panel Cutout
(W) x (H) mm
118.8 x 92.8
Weight
Approx. 230g
NOTE
1) The half-life of backlight is defined as original luminance being reduced by 50% when the
maximum driving current is supplied to HMI. The life of LED backlight shown here is an
estimated value under 25
o
C normal temperature and humidity conditions.
2) The value of the power consumption indicates the electrical power consumed by HMI only
without connecting to any peripheral devices. In order to ensure the normal operation, it is
recommended to use a power supply which the capacity is 1.5 ~2 times the value of the
power consumption.
3) Some models are in the process of application to certification. For more information, please
consult our distributors.
4) The content of this instruction sheet may be revised without prior notice. Please consult our
distributors or download the most updated version at http://www.delta.com.tw/ia/.