Chapter 12 Descriptions of Parameter SettingsMS300
293
3 (auto-acceleration and auto-deceleration–decelerating by the actual load): the drive auto-
detects the load torque and automatically accelerates from the fastest acceleration time and
smoothest start-up current to the setting frequency. During deceleration, the drive automatically
determines the loaded regenerative energy to steadily and smoothly stop the motor in the fastest
deceleration time.
4 (stall prevention by auto-acceleration and deceleration–reference to the acceleration and
deceleration time settings): if the acceleration and deceleration time are within a reasonable
range, the actual acceleration and deceleration time refer to the Pr.01-12–01-19 settings. If the
acceleration and deceleration time are too short, the actual acceleration and deceleration time
are greater than the acceleration and deceleration time settings.
Sets the time required to decelerate from the maximum operation frequency (Pr.01-00) to 0.00
Hz through the CANopen control.