Chapter 12 Descriptions of Parameter SettingsMS300
348
speed with high speed -connection.
Pr.05-24 enables and disables the switch of Y-connection/-connection.
When you set Pr.05-24 to 1, the drive uses the Pr.05-23 setting and current motor frequency,
and switches the current motor to Y-connection or -connection. You can switch the relevant
motor parameter settings simultaneously.
Pr.05-25 sets the switch delay time of Y-connection/-connection.
When the output frequency reaches the Y-connection/-connection switch frequency, the drive
delays according to Pr.05-25 before activating the multi-function output terminals.