Chapter 12 Descriptions of Parameter SettingsMS300
452
14-70
Fault Record 7
14-71
Fault Record 8
14-72
Fault Record 9
14-73
Fault Record 10
Default: 0
Settings
0: No fault record
1: Over-current during acceleration (ocA)
2: Over-current during deceleration (ocd)
3: Over-current during steady operation (ocn)
4: Ground fault (GFF)
6: Over-current at STOP (ocS)
7: Over-voltage during acceleration (ovA)
8: Over-voltage during deceleration (ovd)
9: Over-voltage during constant speed (ovn)
10: Over-voltage at stop (ovS)
11: Low-voltage during acceleration (LvA)
12: Low-voltage during deceleration (Lvd)
13: Low-voltage during constant speed (Lvn)
14: Low-voltage at stop (LvS)
15: Phase loss protection (orP)
16: IGBT overheating (oH1)
18: IGBT temperature detection failure ( tH1o)
21: Over load (oL)
22: Electronics thermal relay 1 protection (EoL1)
23: Electronics thermal relay 2 protection (EoL2)
24: Motor PTC overheating (oH3)
26: Over-torque 1 (ot1)
27: Over-torque 2 (ot2)
28: Under current (uC)
31: EEPROM read error (cF2)
33: U-phase error (cd1)
34: V-phase error (cd2)
35: W-phase error (cd3)
36: cc (current clamp) hardware error (Hd0)
37: oc (over-current) hardware error (Hd1)
40: Auto-tuning error (AUE)
41: PID loss ACI (AFE)
43: PG feedback loss (PGF2)
44: PG feedback stall (PGF3)
45: PG slip error (PGF4)