Chapter 16 PLC Function ApplicationsMS300
722
API
FLT
Convert single-precision floating point number
49
D
P
bit device
Word device
16-bit command
32-bit command (9 steps)
DFLT
Continuous
execution type
DFLTP
Pulse
execution type
Flag signal: none
X
Y
M
K
H
KnX
KnY
KnM
T
C
D
S
D
Notes on operand usage:
Refer to the function specifications table for each device in series
for the scope of device usage
The operand D occupies two consecutive points.
S: Source device. D: Result device.
Converts a BIN whole number into a binary decimal value.
When X11 is ON, converts the whole number corresponding to D0 and D1 into
floating point numbers, and stores the result in D20 and D21.