Chapter 16 PLC Function ApplicationsMS300
734
API
INT
Single-precision floating point number Convert
binary floating point number to BIN whole
number
129
D
P
bit device
Word device
16-bit command
32-bit command (9 STEP)
DINT
Continuous
execution type
DINTP
Pulse
execution type
Flag signal: none
X
Y
M
K
H
KnX
KnY
KnM
T
C
D
S
D
Notes on operand usage:
Refer to the function specifications table for each device in series for
the scope of device usage.
S: the source device to be converted. D: results of conversion.
Converts the content of the register designated by S from a binary floating point
number format to a BIN whole number, and stores the results in D. The BIN
whole number floating point number is discarded.
The action of this command is the opposite of that of command API 49 (FLT).
When X0 = ON, converts the binary floating point number (D1, D0) into a BIN
whole number, and stores the result in (D10); the BIN whole number floating
point number is discarded.
X0
DINT D0 D10