103
NAME VALUE SECURITY
(get/set)
DESCRIPTION
contrast
*Onlyavailablewhenbit1of
"capability_image_c<0~(n‐1)>_basicse
tting"is1
saturationpercent 0~100 4/4 Setsaturationinthenormalized
rang e.
0:Lesssaturation<‐>100:More
saturation
*Onlyavailablewhenbit2of
"capability_image_c<0~(n‐1)>_basicse
tting"is1.
sharpnesspercent 0~100 4/4 Set sharpnessinth enormalized
rang e.
0:Softer<‐>100:Sharper
*Onlyavailablewhenbit3of
"capability_image_c<0~(n‐1)>_basicse
tting"is1
gammacurve
<product
dependent>
0~100 4/4 0:Fine‐turnedgammacurveby
Vivotek.
1:Gammavalue=0.01
2:Gammavalue=0.02
3:Gammavalue=0.03
...
100:Gammavalue=1
*Note:Alt houghwesetgammavalue
to100level,butnotallgammavalues
arevalid.Internalmodulewilltakethe
closestvalidone.Forexample,1~45
mayall bemappedtogammavalue =
0.45,etc.
*Onlyavailablewhen
"capability_image_c<0~(n‐1)>_gamm
acurve"is1
lowlightmode
<product
dependent>
<boolean> 4/4 Enable/disablelowlightmode.
*Onlyavailablewhen
"capability_image_c<0~(n‐1)>_lowligh