7.42 UARTControl
Group:uart(capability_nuart>0andcapability_fisheye=0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] 1/4 NameofthePTZdriver.
ptzdrivers_i<0~19,
127>_location
string[128] 1/4 FullpathofthePTZ driver.
enablehttptunnel <boolean> 1/4 EnableHTTPtunnelchanneltocontrol
UART.
Group:uart_i<0~(n‐1)>nisuartportcount(capability_nuart>0andcapability_fisheye=0)
NAME VALUE S ECURITY
(get/set)
DESCRIPTION
baudrate 300,600,1200,2400,
4800,9600,19200,38
400,57600,115200
4/4 Setbaudra teofCOMport.
databit 5,6,7,8 4/4 Databitsinacharacterframe.
paritybit none,
odd,
even
4/4 Forerrorchecking.
stopbit 1,2 4/4 "1":Onestopbitistransmittedto
indicatetheendofabyte.
"2":Twostopbitsaretransmittedto
indicatetheendofabyte.
Ifyouwanttotransferthe stopbitfo r
150%ofthenormaltimeusedto
transferonebit,the
uart_i<0~(n‐1)>_stopbitshouldbeset
as2andtheuart_i<0~(n‐1)>_databit
setas5aswell.
uartmode rs485,
rs232
4/4 RS485orRS232.
customdrvcmd_i<0~
9>
string[128] 1/4 PTZcommandforcustomcamera.
*onlyavailablewhen
capability_camctrl_c0_rs485=2