VIVOTEK
412 - User's Manual
© 2022 VIVOTEK INC. All Right Reserved
263
8. UsefulFunctions
8.1 Dri vetheDigitalOutput(capability_ndo>0)
Note:Thisre questrequiresViewerprivileges.
Method:GET/POST
Synta x:
http://<servername>/cgi‐bin/dido/setdo.cgi?do0=<value>[&do1=<value>]
[&do2=<value>][&do3=<value>]
Wherestateis0or1;“0”meansinactiveornormalstate,while“1”meansactiveortriggeredstate,
andtriggertimeisindicatedinseconds.
PARAMETER VALUE DESCRIPTION
do<num> state[triggertime]
Where"state"is0,1.
“0”meansinactiveor
normalstatewhile
“1”meansactiveor
triggeredstate.
Where"triggertime"
isreset timeafter
statechange.
Ex:do0=1
Settingdigitaloutput#1totriggerstate.
Ex:do0=0[30]
Settingdigitaloutput#1tonormalstate,waiting30
seconds,settingittotriggerstate.
Example:Drivethedigitaloutput#1totriggeredstate,resetdo0after20secondsandredirectto
anemptypage.
http://myserver/cgi‐bin/dido/setdo.cgi?do0=1[20]
8.2 QueryStatusoftheDigitalInput(capability_ndi>0)
Note:Thisrequestrequire sViewerprivileges
Method:GET/POST
Synta x:
http://<servername>/cgi‐bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
Ifnoparameterisspecified,allofthedigitalinputstatuseswillbereturned.