EasyManua.ls Logo

Delta Vivotek IB9391-EHTV-v2 - Page 412

Delta Vivotek IB9391-EHTV-v2
472 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
412 - User's Manual
© 2022 VIVOTEK INC. All Right Reserved
263
8. UsefulFunctions
8.1 Dri vetheDigitalOutput(capability_ndo>0)
Note:Thisre questrequiresViewerprivileges.
Method:GET/POST
Synta x:
http://<servername>/cgi‐bin/dido/setdo.cgi?do0=<value>[&do1=<value>]
[&do2=<value>][&do3=<value>]
Wherestateis0or1;“0”meansinactiveornormalstate,while“1”meansactiveortriggeredstate,
andtriggertimeisindicatedinseconds.
PARAMETER VALUE DESCRIPTION
do<num> state[triggertime]

Where"state"is0,1.
“0”meansinactiveor
normalstatewhile
“1”meansactiveor
triggeredstate.
Where"triggertime"
isreset timeafter
statechange.
Ex:do0=1
Settingdigitaloutput#1totriggerstate.
Ex:do0=0[30]
Settingdigitaloutput#1tonormalstate,waiting30
seconds,settingittotriggerstate.
Example:Drivethedigitaloutput#1totriggeredstate,resetdo0after20secondsandredirectto
anemptypage.
http://myserver/cgi‐bin/dido/setdo.cgi?do0=1[20]
8.2 QueryStatusoftheDigitalInput(capability_ndi>0)
Note:Thisrequestrequire sViewerprivileges
Method:GET/POST
Synta x:
http://<servername>/cgi‐bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
Ifnoparameterisspecified,allofthedigitalinputstatuseswillbereturned.