PARAMETER VALUE DESCRIPTION
function focus,
auto,
scan,
stop,
positioning,
irisopen,
irisenable,
resetfocus
focus–Movefocusmotor
auto–Performautofocus
scan–Performfoc usscan
stop–Stopcurrentoperation
positioning–Positionthemotors
resetfocus–resetfocuspositiontodefault
irisopen–Fullyopeniris.Itwillmaintainfullyopeniris
statusuntilsendingfunction=irisenablecgi.
irisenable–retur nbacktousersettingstatusofiris.
direction direct,
forward,
backward
Motor ’smovingdirection.
Itworksonlyiffunction=focus.
position <motor_start>~
<motor_end>
Motor ’sposition.
Itworksonlyiffunction=focusanddirection=direct.
<motor_start>:remote_focus_zoom_motor_startor
remote_focus_focus_motor_start,
<motor_end>:remote_focus_zoom_motor_endor
remote_focus_focus_motor_endrepliedfrom
"function=getstatus"
steps1~30 Motor’smovingsteps.
Itworksonlyiffunction=focusanddirection=forwardor
direction=backward.
*Motorwillstopwhenitreachesto<motor_start>or
<motor_end>.
* This parameter is for additional fine-tune, the value is from 1
to 30.
irisN/AOpenirisornot.
Itworksonlyiffunction=autoorfunction=scan.
Synta x:(forqueryAPI)
http://<servername>/cgi‐bin/admin/remotefocus.cgi?channel=<value>&[function=<value>]