PARAMETER VALUE DESCRIPTION
function getstatus,
onetimeauto
"onetimeauto ":CamerawillautomaticallyadjusttheIR
zoneone timeonly.
"getstatus":InformationofoptimizedIRcontrolstatusand
returnvalueasbelow:
optimizedir_c<0~(n‐1)>_irmode:
IndicatetheIRcurrentmode,availablevalueis“auto”and
“manual”mode.
optimizedir_c<0~(n‐1)>_irnum:
ThenumberofIRthatcamerasupports.
optimizedir_c<0~(n‐1)>_irstrength:
Onlyavailablewhenirmodeissetasmanual.It’sasetof
integers,whichindicatethestrengthofeachIRLED(e.g.
23,45,100,100).
optimizedir_c<0~(n‐1)>_irstatus:
CurrentIRstatus,normal/adjusting:
"normal":theIRLEDstrengthhasbeenfixe d.
"adjusting":theIRLEDstrengthisadjusting.
optimizedir_c<0~(n‐1)>_supportmode:
“auto”:automaticallyadjustth eIRcontrol.
“manual”:manualadjustment.
Example:
http://myserver/cgi‐bin/admin/optimizedir.cgi?function=getstatus
Response:
HTTP/1.0200OK\r\n
Cache‐control:no‐cache\r\n
Pragma:no‐cache\r\n
\r\n
"optimizedir_c0_irmode='auto'"
"optimizedir_c0_irnum='5'"
"optimizedir_c0_irstrength='1,97,100,100,100'"
"optimizedir_c0_irstatus='normal'"
Synta x:(forcontrolAPI)
http://<servername>/cgi‐bin/admin/optimizedir.cgi?channel=<value>&operation=<value>&irmode=
manual[&strength=<value>]–SetIRstrength