Example
The î™°rst eight bytes are normally
"00FFFFFFFFFFFF00".
*If the AVR and the TV are not con-
nected via HDMI, the correct register
value cannot be veriî™°ed.
When the results of check item (42) are "03"
(Detection of HPD is OK / Detection of RXSENSE is OK )
Check item(43). Check the Monitor EDID :
â‘ Unplug the AC cord. Plug the AC cord into a power outlet.
② Send the transmission command "m_2" from Termite.exe.
Are the î™°rst eight bytes of the returned value "00FFFFFFFFFFFF00"?
Check item(44). Checking the TMDS :
Check the TMDS waveform at the following test
point.
Check item(45). Check communication with the
monitor :
Are waveforms of "DDCSCK" and "DDCSDA"
observed at the test point near the HDMI output
terminal (N1030)?
Checking the EDID register. (Monitor2)
HDMI Tx (U1039) is faulty.
Replace with a new device.
Recheck from check item (4).
If it does not work, replace the PCB.
HDMI Tx (U1039) is faulty.
Replace with a new device.
Check for a short circuit in the TMDS line.
If there is no problem, the HDMI Tx
(U1039) is faulty.
Replace with a new device.
HDMI Tx (U1039) is faulty.
Replace with a new device.
NOYES NOYES
less than 100KHz
5V
5V
This diagram shows an example of the DDC commu-
nication waveform.
-The high level voltage is 5V.
-The frequency of the DDC CLK is 100 KHz or less.
Check at each test point.
YES NO
99
Caution in
servicing
Electrical Mechanical Repair Information Updating