JIG FOR SERVICING
Use the following jigs (extension cable kit) when repairing the PCBs.
Order with your dealer for the jigs your dealer if necessary.
CAUTION : Incorrect connections may cause malfunction.
Connection of Jig for DIGITAL PCB
---Items to Be Prepared---
8U-110084S : EXTENSION UNIT KIT : 1 Set
8U-110136S : EXTENSION UNIT KIT : 1 Set
Insulation sheet (Not supplied) : 3 sheet
Ground lead (Not supplied) : 2 pc
-Proceeding-
(1) Remove the screws.
(2) Remove the connector PCB.
↑Shooting direction: A↑
x30
x14
x2
CUT
N1040
N1018
N1022
N1023
(3) Remove the DIGITAL PCB from the chassis and turn it over.
Place an insulation sheet larger than the PCB underneath the DIGITAL PCB.
b
Connect the earth of the PCB to the chassis using an earth wire, etc.
N5000
CN4203
CN4202
CN4201
CN4204
Insulation sheet
PCB DIGITAL
PCB VIDEO
PCB INPUT
CHASSIS-HDMI CONNECTOR
CHASSIS-COMPOSITE CONNECTOR
177
Caution in
servicing
Electrical Mechanical Repair Information Updating