DERRICK
®
CORP. - MOTOR DATA SHEET
JFS M:\Motor Docs\Pe-s-245.doc (Maintenance)
U:\Motor PDFs\Pe-s-245.pdf (view/print)
DOC# PE-S-245-05
Wire Code
Power Black, White & Red
Ground Green
Thermal Switch Orange & Blue
1500 RPM
MODEL: EX VIBRATOR - 50 HZ - (EXPLOSION PROOF TERMINAL BLOCK STYLE)
Vibrator Model
EX-215/220-50 EX-230/240-50 EX-380/400-50 EX-415-50 EX-440-50
Voltage [Volts] 215/220 230/240 380/400 415 440
Phase / Frequency [Hz] 3/50 3/50 3/50 3/50 3/50
Speed [RPM] 1500 1500 1500 1500 1500
Rated Horsepower [HP] 2.5 2.5 2.5 2.5 2.5
Current @ Idle / Full Load
[Amps]
3.6 / 7.1 3.3 / 6.5 2.1 / 4.0 1.9 / 3.8 1.8 / 3.6
Locked Rotor Current [Amps]
/ Locked Rotor Code
28.4 / D 26.0 / D 15.6 / D 15.1 / D 14.2 / D
Fuse - Non Delay [Amps] 20 20 12 10 10
Overload protection [Amps] 8 7 5 4 4
Data below is common to all model EX-50 vibrators.
Insulation class
Ambient temperature
Operating temperature code
Maximum temperature rise
Duty
Thermal switch rating
Thermal switch type
Thermal switch temperature
Power factor - operations
Efficiency - running
Service Factor
NEMA design
Ingress Protection
Weight
Hazardous location (listed as)
Listing agency
Hazardous location (listed as)
Listing agency
F
55º C
T3C
46º C by Resistance
CONTINUOUS
Pilot Duty 720VA, 110 – 600VAC
Normally Closed
Opens @ 145º C / Closes @ 140º C
99.13
98%
1.0
TENV
IP 56
415 lbs.-(189 kg)STEEL / 290 lbs.-(132 kg)ALUMINUM
CLASS 1 GROUPS C, D / CLASS 2 GROUPS E, F, G
UL
EEx d IIB T3
DEMKO
NOTE:
Derrick
®
vibrators are fixed load devices with no means of altering the loading or power
consumption. Power factor correction capacitors are not recommended for this motor.
02/11/05 – Rev. 5 Page 1 of 1
37.7500 9.0000