Provides instructions for operating and installing the DESA direct-vent fireplace.
Highlights essential safety precautions to prevent fire, explosion, injury, or death.
Details dangers of carbon monoxide and signs of poisoning, emphasizing proper installation.
Outlines crucial rules for safe fireplace operation, including gas leak procedures.
Illustrates key components of the Tudor Direct-Vent Fireplace with Millivolt Ignition.
Specifies compliance requirements with national and local gas installation codes.
Explains key features of the direct-vent fireplace, including venting and ignition.
Guides selection of a safe and efficient location, detailing clearance and placement considerations.
Defines required air space clearances between the fireplace and surrounding combustible materials.
Provides instructions and diagrams for framing the fireplace and installing mantels.
Details specific clearance requirements for the vent termination cap based on location.
Lists essential safety measures and actions that void the warranty during venting installation.
Outlines planning steps for horizontal and vertical direct-vent installations.
Explains how to connect vent pipes and requirements for wall penetrations.
Details installing a siding standoff for combustible exterior walls with horizontal venting.
Describes the process of connecting the vent cap to the horizontal vent pipe and installing the firestop.
Illustrates typical mounting of the horizontal termination cap with siding standoff.
Shows various configurations for ground floor installations using square and round terminations.
Details configurations for corner installations and ground floor venting through walls.
Explains snorkel termination for installations requiring a vertical rise or below grade.
Provides step-by-step instructions for vertical venting, including roof and ceiling penetrations.
Details the process for installing a firestop in a flat ceiling for vertical vent termination.
Offers guidance on fireplace installation at higher elevations, including orifice adjustments.
Lists available DESA International pipe and vent kits and accessories.
Provides instructions for installing optional blower accessories for improved heat distribution.
Details requirements and procedures for connecting the gas supply piping to the fireplace.
Guides the connection of the fireplace to the gas supply, including flexible gas lines.
Explains how to test gas piping and connections for leaks using leak detection fluid.
Details the installation of remote control receiver and hand-held units for fireplace operation.
Provides instructions for safely removing and replacing the fireplace glass door assembly.
Guides the installation of optional brick liner kits for aesthetic enhancement.
Step-by-step instructions for correctly placing logs, lava rock, and ember material in the firebox.
Crucial safety precautions to follow before attempting to light the fireplace pilot.
Step-by-step guide for safely lighting the fireplace pilot and main burners.
Alternative procedure for lighting the pilot using a match if the piezo ignitor fails.
Instructions for using optional remote controls for fireplace operation and temperature settings.
Details on operating the GHRC series remote control for burner on/off functionality.
Explains operation of GHRCT(A) series remote for AUTO and manual modes, including temperature control.
Guidance on operating the GWMT1 wall-mounted thermostat for fireplace temperature control.
Instructions for operating the optional blower accessory for enhanced heat distribution.
Procedures for inspecting pilot assembly and burner flame patterns for proper operation.
Instructions for cleaning the glass door, including recommended cleaners and frequency.
Guidance on cleaning pilot assemblies and burners using compressed air and vacuums.
Procedures for cleaning logs and replacing broken logs or ember material.
Annual inspection guidelines for the venting system to check for corrosion and integrity.
Troubleshooting steps for when no spark is generated at the pilot upon pressing the ignitor button.
Steps to resolve issues where a spark is present but the pilot does not ignite.
Diagnosing and fixing problems where the pilot flame extinguishes after the control knob is released.
Addresses problems like burners not lighting, delayed ignition, and backfiring during combustion.
Troubleshooting initial smoke or odor, and whistling noises when the burner is lit.
Diagnosing soot on glass and ticking noises from thermal expansion/contraction.
Procedures for identifying and rectifying unwanted odors, emphasizing gas leak checks.
Troubleshooting why the fireplace shuts off during use or if a gas odor is present.
Addresses dark residue on logs, potentially due to log placement or blocked burner inlets.
Details on obtaining original replacement parts, including warranty procedures.
Technical specifications for various models, including dimensions, gas type, and pressure.
Provides hints for low gas pressure and information on contacting DESA International for technical assistance.
Lists various optional accessories available for purchase to enhance the fireplace's functionality and appearance.
Diagram showing an exploded view of fireplace components for easy identification.
A comprehensive list of replaceable parts categorized by key number, description, and quantity.
Provides information on the limited two-year warranty, coverage, exclusions, and claim procedures.