116192-01M32
WARNING: Only parts sup-
plied by the manufacturer should
be used when replacing broken
or damaged glass door panel
(see Replacement Parts, page
37). This glass door panel is
a complete unit. No substitute
materials may be used.
CAUTION: Wear gloves and
safety glasses while handling
or removing broken glass. Do
not remove if glass is hot. Keep
children and pets away from
glass.
If glass has been broken, carefully remove
glass door (see Removing/Replacing Glass
Door, page 25). Vacuum all glass pieces with
a shop vac.
CAUTION: Do not vacuum if
pieces are hot.
Use only the tempered glass door replace-
ment intended for this replace (see Replace-
ment Parts, page 37 for detail on ordering).
No substitutions may be made. See Remov-
ing/Replacing Glass Door, page 25 for instruc-
tions for replacing glass door.
WARNING: Do not operate
replace with the glass door
unlatched, removed, cracked
or broken.
PILOT AND BURNERS
Remove ember material before cleaning
burners and replace when cleaning is
complete.
Burner and controls should be cleaned
with compressed air to remove dust, dirt
or lint.
Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt or lint.
LOGS
If you remove logs for cleaning, refer to
Installing Lava Rock and Glowing Embers,
page 26, to properly replace logs.
Use a vacuum cleaner to remove any
carbon buildup on logs.
Replace log(s) if broken. See Replacement
Parts on page 37.
Replace ember material periodically
as needed. See Replacement Parts on
page 37.
VENTING SYSTEM
Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced im-
mediately by a qualied service person.
2. Remove the vent cap and shine a ash-
light into the vent. Remove any foreign
material.
3. Check for evidence of excessive con-
densation. Continuous condensation can
cause corrosion of caps, pipes and ttings
and can be caused by having excessive
lateral runs, too many elbows or exterior
portions of the system being exposed to
cold weather.
4. Inspect joints to verify that no pipe section
or tting has been disturbed and loos-
ened. Check mechanical supports such
as wall straps for rigidity.
CLEANING AND MAINTENANCE
Continued

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Desa TC36N Series and is the answer not in the manual?

Desa TC36N Series Specifications

General IconGeneral
BrandDesa
ModelTC36N Series
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals