Rev 07/04/2015
4
Parameter
Description
5 PANS
115V
5 PANS
230V
CONTAINED
230V TROLLEY
VPD
battery voltage threshold to detect presence of
battery [V/10]
5
5 5 5
TBK
delay time before safety turn
circuit [sec]
60
60 60 60
BOF battery voltage offset [V/10] 0
0 0 0
MST max air temperature during thawing [°C/°F] 50 50
50 50
OFH not used 3
3 3 3
PAT air temperature in pre-thawing cycle [°C/°F] 43 43
43 43
PFT evaporator fan speed in pre-thawing cycle [%] 10
10 10 10
PAC air temperature in pre-soft cooking cycle [°C/°F] 43 43
43 43
PFC
evaporator fan speed in pre
[%]
6
6 6 6
HHL lower differential heating action [°C/°F] 5 5
5 5
HHH upper differential heating action [°C/°F] 5 5
5 5
MRV nominal mains voltage [V] 115
230 230 220
PRF evaporator fan declared power [W] 100
100 100 100
CMR
evaporator speed fan index during RH% control
[num]
10
10 10 10
CPR not used 10
10 10 10
CIN not used 0
0 0 0
SPS not used 7
7 7 7
TBC not used 5
5 5 5
LPT not used 0
0 0 0
POF not used 0
0 0 0