Details main power connection requirements and NFPA72 color coding for safety.
Explains fire loop control bypass and connection to building fire alarm systems.
Describes the ON-OFF switch for de-energizing the unit for service and adjustments.
Details the 1 Amp circuit breaker for protecting against high current loads.
Instructions for setting output voltage to 24 volts DC using select switches.
Information on output terminals providing 24 volts at 1 amp maximum, protected by a PTC fuse.
Details connections for optional lead acid batteries for 24-volt backup.
Explains the Power Good LED indicator that glows green when 24 volts is supplied.
Details the requirement for normally open contacts for door latch activation and hold.
Describes the potentiometer to adjust latch retraction hold time up to 30 seconds.
Specifies connections for ER power wires, noting polarity and terminal markings.
Explains the red LED indicating when the output voltage to the latch retraction device is energized.
Details the relay output for signaling a door opener, delayed by 0.5 to 3 seconds.
Describes the green status LED that glows when the relay is energized.
Instructions for adjusting the operator signal relay delay from 0.5 to 3 seconds.
Information on the optional 12 volt DC power supply module and ordering details.
Table listing recommended wire gauges and maximum lengths for two-conductor cable.