INSTRUCTIONS FOR 81-800
Owner's Copy
101339 Page 1
Question and Answer IconNeed help?

Do you have a question about the Detex 800 Series and is the answer not in the manual?

Summary

DETEX 81-800 Operation Manual

DETEX Model 81-800 Connection Diagram and Operation

Main Power Connection

Details main power connection requirements and NFPA72 color coding for safety.

Fire Loop Control

Explains fire loop control bypass and connection to building fire alarm systems.

Main ON-OFF Switch

Describes the ON-OFF switch for de-energizing the unit for service and adjustments.

1 Amp Circuit Breaker

Details the 1 Amp circuit breaker for protecting against high current loads.

Output Voltage Select Switches

Instructions for setting output voltage to 24 volts DC using select switches.

Output Terminals

Information on output terminals providing 24 volts at 1 amp maximum, protected by a PTC fuse.

Optional Battery Backup Connections

Details connections for optional lead acid batteries for 24-volt backup.

Power Good Indicator

Explains the Power Good LED indicator that glows green when 24 volts is supplied.

Control Inputs

Details the requirement for normally open contacts for door latch activation and hold.

Door Hold Delay Adjustment

Describes the potentiometer to adjust latch retraction hold time up to 30 seconds.

Output to ER Device

Specifies connections for ER power wires, noting polarity and terminal markings.

Door Output Activity Indicator

Explains the red LED indicating when the output voltage to the latch retraction device is energized.

Door Opener Output Relay

Details the relay output for signaling a door opener, delayed by 0.5 to 3 seconds.

Door Operator Status Indicator

Describes the green status LED that glows when the relay is energized.

Door Operator Delay Adjustment

Instructions for adjusting the operator signal relay delay from 0.5 to 3 seconds.

Optional 12 Volt Power Module

Information on the optional 12 volt DC power supply module and ordering details.

Recommended Wire Sizes

Table listing recommended wire gauges and maximum lengths for two-conductor cable.

Detex 800 Series Specifications

General IconGeneral
BrandDetex
Model800 Series
CategoryPower Supply
LanguageEnglish