Quick Install Guide For Model AO19
Low Energy Automatic Door Operator
Push Type
July 3, 2008
P/N 103186
Parts Needed
1. Header Box/Cover
2. AO19 Operator
3. 3-Point Arm Assy – Push
4. Controller Module
Tools Required
1. Phillips Screwdriver
2. Vise Clamps
3. Ladder
4. Appropriate screws to
secure to wall
5. Safety Glasses
Cover
AO19 Low Energy
Automatic Door Operator
Controller Module
P/N 104792
3-Point Arm Assy.-Push
P/N 104798
INSTALLATION – PUSH MODEL
1. INSTALLATION PREPARATION
Locate Phillips screws inside at the top corners.
Remove these screws and separate the header
from the hanger plate
The hanger plate should be located 5/8" from the
outside edge of the hinge jam.
It should be level and flush with the bottom of the
header.
Secure hanger plate with vise clamps to the
header and drill 3/16" holes.
Fasten hanger plate.
2. INSTALLATION OF HANGER PLATE
3. PLACE OPERATOR ON HANGER PLATE
Lift the operator and lower into webs of the hanger plate. Ensure both top
and bottom are engaged.
Once seated, gently pull down until the unit is completely flush and secure
with screws on top corners.
Note: Secure to solid foundation or wall studs.
Pg. 1

Other manuals for Detex AO19

Question and Answer IconNeed help?

Do you have a question about the Detex AO19 and is the answer not in the manual?

Detex AO19 Specifications

General IconGeneral
ModelAO19
MountingSurface Mount
Warranty1 Year Limited
Power Source9V Battery
Door TypeWood, Metal
ComplianceUL
Housing MaterialMetal
Door Thickness1-3/4" (44mm) standard