Details the conditioning and diagnostic system for HV vehicle batteries and its delivery scope.
Provides technical specifications for the device, including input, output, and environmental data.
Specifies input voltage range, frequency, inrush current, and current harmonics.
Outlines output voltage range, operation modes, charging current limit, efficiency, and protection features.
Details storage and operating temperature, protection class, pollution degree, humidity, and altitude.
Instructions for unpacking, checking for damage, and proper storage of the device.
Guides users on checking the delivery for transport damage and reporting issues.
Identifies and explains warning symbols found on the device's housing.
Provides guidance on the environmentally friendly disposal of packaging materials.
Offers recommendations for storing the device to prevent damage from environmental factors.
Explains how to view and adjust the charging current limit for the battery module.
Details how to set the target voltage for the connected battery module.
Outlines the procedure to start the conditioning process, including security code entry.
Illustrates the charging and discharging operating screens and their elements.
Instructions for selecting the preferred display language for the device interface.
Explains how to access and view detailed cell voltage and temperature measurements.
Details accessing and configuring advanced parameters via the password-protected SuperUser menu.
| Output Voltage | 60 VDC |
|---|---|
| Output Current | 20 A |
| Output Power | 1200 W |
| Input Frequency | 47 - 63 Hz |
| Cooling | Internal fan |
| Protection Features | Overvoltage protection, Overcurrent protection, Overtemperature protection, Short circuit protection |
| Safety Standards | EN 60601-1 |
| EMC Standards | EN 60601-1-2 |