Here we hold both lights at Red for 30 seconds to give traffic time to traverse the controlled
area. Then Red + Amber for two seconds followed by Green for 60 seconds. We then stop the
traffic with Amber for 3 seconds followed by Red. Again we hold both lights at Red for 30 sec-
onds before letting the other queue through at line 6.
To watch it happen, set relays 21, 25 & 29 to K1, K2 & K3 and set relays 24, 28 & 32 to K4, k5
& K6.