DEVI Iceguard cable specifications
Application Roof / gutters / downpipes
Colour Black
Dimensions 13.1 x 6 mm
Sheath Polyolefin UV
Voltage 230 V
Effect 18 W/m at 0°C (approx. 36 W/m in ice)
Capacitive leak current 30 mA/km cable
Min. installation temperature -5°C
Min. start-up temperature -40°C
Max. temperature ON / OFF 65 / 85 °C
Length of cold-lead 5 m
The effect stated is measured with the Iceguard heating cable installed on an insulated metal pipe.
When self-limiting cables are installed in the open, the effect may be reduced by approx. 50%.
When planning the installation it must be considered that self-limiting cables may reduce the operational
effect over several years.