DEVI DEVIreg 850 Specifications

General IconGeneral
TypeElectronic thermostat
IP ClassIP20
Frequency50/60 Hz
Accuracy±0.5°C
Protection ClassII
Max Load16A
InstallationDIN Rail
MountingDIN rail
OutputRelay
Storage Temperature-20°C to +65°C
Relative HumidityMax. 95% RH, non-condensing
Weight150g

Summary

User Manual

System Overview

Explains the DEVIreg™ 850 system's capability to manage up to 2 independent outdoor areas.

Typical Installation Components

Details the essential components for a typical DEVIreg™ 850 ice and snow melting system installation.

General Operation

Describes how to operate the DEVIreg™ 850 using its buttons and display.

Button Functions

Details the functions of the three buttons and special button combinations for operation.

Display Icons

Explains the meaning of the special icons shown on the DEVIreg™ 850 display.

Menu System Navigation

Explains how to navigate the DEVIreg™ 850 menu system for system configuration and monitoring.

Operation Alarms

Details common alarms, their causes, and solutions for the DEVIreg™ 850 system.

Parameter Configuration

Explains how to change system parameters to adjust performance for roof and ground systems.

Roof System Parameters

Details adjustable parameters for the roof system: temp, moisture, post-heat, priority, and alarms.

Ground System Parameters

Details adjustable parameters for the ground system: temp, standby, moisture, post-heat, priority, and alarms.

Installer Manual

System Overview

Describes the DEVIreg™ 850's capability to handle up to 2 independent areas and system components.

Typical System Components

Lists the essential components for a typical DEVIreg™ 850 ice and snow melting system.

Unit Placement

Provides guidelines for mounting the DEVIreg™ 850 and power supply, including environmental conditions.

System Connection Steps

Outlines the recommended order and conditions for wiring the DEVIreg™ 850 and sensors.

System Installation Steps

Guides the user through the DEVIreg™ 850 installation process, including system type selection.

General Installation Setup

Covers initial setup steps like power on, language selection, and system configuration type.

Roof System Installation

Details the procedure for installing a single roof system with the DEVIreg™ 850 controller.

Ground System Installation

Details the procedure for installing a single ground system with the DEVIreg™ 850 controller.

Combi System Installation

Guides the installation of a combi system (1 roof and 1 ground) with the DEVIreg™ 850.

Dual System Installation

Details the procedure for installing a dual system (2 roof or 2 ground) with the DEVIreg™ 850.

System Modification Options

Outlines possible modifications: reactivating sensors, replacing sensors, and adding sensors.

Reactivating Passive Sensors

Describes the process for reactivating passive sensors in the DEVIreg™ 850 system.

Replacing Malfunctioning Sensors

Details the steps to replace a malfunctioning sensor with a new one in the DEVIreg™ 850.

Adding Extra Sensors

Explains how to add an extra sensor to an existing DEVIreg™ 850 installation.

Technical Specifications

Technical Data Overview

Provides key technical specifications for the DEVIreg™ 850, sensors, and power supply.

Factory Settings

Lists the default factory settings for various functions in the Roof and Ground systems.

Appendix A: Menu System

Main Menu Navigation

Illustrates the main menu structure for selecting and configuring System A and System B.

System Menu Options

Details the options available within the system menu for operating mode, sensor measurements, and parameters.

Viewing Sensor Measurements

Shows how to view sensor measurements for both Roof and Ground systems.

Viewing System Parameters

Details how to view system parameters for both Roof and Ground systems.

Installer Menu Configuration

Guides through setting parameters, renaming systems/sensors, and changing system settings in the installer menu.

Changing System Configuration

Illustrates the process for adding or replacing sensors within the DEVIreg™ 850 system.

Viewing System Statistics

Explains how to view operating time, running time, relay operations, and firmware versions.

Appendix B: How It Works

Roof System Operation

Explains the automated operation of the roof system, including standby, melting, and post-heating phases.

Ground System Operation

Details the automated operation of the ground system, including standby, melting ice/snow, and post-heating.

Post-heating Functionality

Explains the post-heating function for both roof and ground systems, and its impact on measurements.

Balancing Security and Energy Use

Provides guidance on adjusting parameters for high security/high energy or low security/low energy operation.

Appendix C: PSU and Feeder Cable

Ground System Cable Lengths

Specifies maximum cable lengths for ground systems based on PSU and cable type.

Roof System Cable Lengths

Specifies maximum cable lengths for roof systems based on PSU and cable type.

The DEVI Guarantee

Guarantee Terms and Conditions

Outlines the terms, conditions, and coverage of the DEVI product guarantee.

Guarantee Certificate Details

Provides the form for filling out the DEVI guarantee certificate with installation and product details.