35
Security and energy consumption
High security – higher energy consumption
If a high degree of security against ice and snow is wanted, make the following adjust-
ments of the operation parameters:
t*ODSFBTFUIFTUBOECZUFNQFSBUVSF
t*ODSFBTFUIFNFMUJOHUFNQFSBUVSF
t%FDSFBTFUIFNPJTUVSFMFWFMDMPTFUPTFUUJOH
t1SPMPOHUIFQPTUIFBUQFSJPE
This will give a high degree of security in even dry areas.
Low security – lower energy consumption
Conversely, low energy consumption and a moderate level of security against ice and
snow could be prioritized. In this case make the following adjustments of the operation
parameters:
t%FDSFBTFUIFTUBOECZUFNQFSBUVSF
t%FDSFBTFUIFNFMUJOHUFNQFSBUVSF
t*ODSFBTFUIFNPJTUVSFMFWFM
t4IPSUFOUIFQPTUIFBUQFSJPE
This will give relatively low energy consumption, but the area may remain wet and icy
in short periods.
The factory settings are average values providing a relatively high degree of secu-
rity and moderate energy consumption.