Installer Manual
Installation of combi system
The installation of a DEVIreg™ 850 with 1 roof and 1 ground system has been selected.
It is optional if the sensors are connected to the DEVIreg™ 850 before power on or dur-
ing the installation.
The rst installed system (System A) is using the output System A.
The second installed system (System B) is using the output System B.
It is freely selectable if System A should be the roof or ground system. However it is
preferable that System A is the roof system, since System A is shown on the upper line
of the display. Please refer to the description of the Display and Combined view in the
user manual.
If sensors for System A are not connected - do it now!
Press or wait…
Connect sensors:
System A
System is being scanned to nd type of connected
sensors…
System A
Scanning...
Select system type: Roof (if roof system is preferred as
System A)
System type:
Roof
Wait until correct number of sensors for System A is
found.
1 Roof sensor
found. Accept?
Press when all sensors are found…
System A is installed…
System A!
Installed
If sensors for System B are not connected - do it now!
Press or wait…
Connect sensors:
System B
System is being scanned to nd type of connected
sensors…
System B
Scanning...
Wait until correct number of sensors for System B is
found.
System type:
Ground
Press when all sensors for System B are found…
3 Ground sensors
found. Accept?

Other manuals for DEVI DEVIreg 850

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DEVI DEVIreg 850 and is the answer not in the manual?

DEVI DEVIreg 850 Specifications

General IconGeneral
BrandDEVI
ModelDEVIreg 850
CategoryController
LanguageEnglish

Related product manuals