EasyManua.ls Logo

DeVilbiss D26563 - User Manual

DeVilbiss D26563
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Record All Information
for future reference:
Brand:
Purchase Date:
Model #:
Serial #:
Questions? 1-800-888-2468
Register your product online
www.devap.com
CONSUMER SAFETY INFORMATION . .2
SAFETY GUIDELINES/DEFINITIONS . .2
SAFETY INSTRUCTIONS . . . . . . . . . .2-8
ASSEMBLY . . . . . . . . . . . . . . . . . . . .9-11
OPERATION . . . . . . . . . . . . . . . . . .12-14
MAINTENANCE . . . . . . . . . . . . . . .15-16
STORAGE . . . . . . . . . . . . . . . . . . . .17-18
WATTAGE CALCULATIONS . . . . . . .17-19
TROUBLESHOOTING GUIDE . . . . . . .20
WARRANTY . . . . . . . . . . . . . . . . . . . . .21
QUICK FACTS . . . . . . . . . . . . . . . . . . .22
ESPAÑOL . . . . . . . . . . . . . . . . . . . . . . . . . . .23-40
FRANÇAIS . . . . . . . . . . . . . . . . . . . . . .45-68
READ AND SAVE THESE INSTRUCTIONS
Generator
Operator’s Manual
Part No. D26563 Rev. 0

Questions and Answers

  • G
    Gerald JenkinsAug 12, 2025
    Why won't my DeVilbiss Portable Generator start?
    • R
      Randy SmithAug 12, 2025
      Your DeVilbiss Portable Generator might not start due to several reasons: * It may be low on fuel or oil, so add fuel or oil. * The ignition switch might be in the "Off" position; turn it to "ON". * The spark plug could be faulty, requiring replacement. * The choke might be in the wrong position, so adjust it accordingly. * The fuel shut-off valve could be closed; open it. * The unit might be loaded during start-up; remove the load. * The spark plug wire might be loose; attach it to the spark plug.
  • K
    khansenAug 19, 2025
    What to do if my DeVilbiss Portable Generator has no electrical output?
    • S
      Sandra BrownAug 20, 2025
      If your DeVilbiss Portable Generator has no electrical output, consider these potential causes: * A faulty receptacle may need replacement by a service center. * A tripped circuit breaker should be depressed and reset. * A defective capacitor may require replacement by a service center. * A faulty power cord should be repaired or replaced. * A tripped GFCI switch breaker (if equipped) should be depressed and reset.
  • K
    Kevin SuarezAug 27, 2025
    How to fix repeated circuit breaker tripping on DeVilbiss D26563?
    • J
      Jordan WalkerAug 27, 2025
      Repeated circuit breaker tripping on your DeVilbiss Portable Generator can be due to: * An overload, in which case you should reduce the load. * Faulty cords or equipment. Check for damaged, bare, or frayed wires on your equipment and replace if necessary.
  • K
    Kimberly RobbinsSep 3, 2025
    What to do if my DeVilbiss D26563 is overheating?
    • S
      Stacey GriffinSep 3, 2025
      If your DeVilbiss Portable Generator is overheating: * The generator might be overloaded; reduce the load. * There may be insufficient ventilation; move the generator to a location with an adequate supply of fresh air.

DeVilbiss D26563 Specifications

General IconGeneral
ModelD26563
TypePortable Generator
Starting Wattage6500 Watts
Power Output120/240V
Fuel TypeGasoline
Engine Type4-Stroke OHV
Run Time10 hours at 50% load
Voltage120/240V
Starting MethodRecoil Start
EngineDeVilbiss Engine
Tank Capacity4 gal
Noise Level68 dB at 23 ft
Outlet Types2x 120V 20A (5-20R), 1x 120/240V 30A (L5-30R)

Related product manuals