5.3.3 TIMER SETTING1hour-24hours:
The timer has two ways of operation:
To turn off
(When power on)
To turn on
(When power off)
Cancel timer
5.3.4 Automatic Defrost
At low room temperatures, frost may build up at the evaporator during
operation. The unit will automatically start defrosting and the POWER
LED will begin blinking. The defrost control sequence is as follows:
A. If the unit is operating in the cooling or drying operation and the
ambient temperature sensor senses the evaporator coil temperature is
below -1°C, the compressor will stop operating for 10 minutes or until
the coil temperature gets up to 7. Then the unit will restart to cool
operating mode.
B. When the unit operates in the heating or drying operation, once the
coil temperature sensor senses the temperature of the evaporator is
Press Timer key to
turn on the timer
function.
Press Timer key to
turn on the timer
function.
Press Up/Down
repeatedly to set the
delay OFF time.
Press
Up/Down
repeatedly to set the
delay ON time.
Press Up/Down repeatedly until the LED shows
‘00’.
Note: Pressing POWER will also cancel off the
timer setting.