the stop time, the system cancels this heating phase.
6. Press the "Set" button (13) to confirm the first period.
7. Repeat the above procedure to set the timer for the remaining three segments. If you do
not wish to set any further heating segments press the “Setbutton repeatedly until you
reach the end of heating segment four and the heater will store solely the first heating
segment.
Power Off
Press the power button (20) to turn the heater on or off. If you shut down the system while
it is in automatic mode, it will work according to the scheduled procedure.
However, if the unit is to be switched off for a long time, you must switch the system to
manual mode and then off. If the system is outside the preset timer, it switches off 1
second after pressing the power button (20).
Half Power and Full Power Selection
Press the heating power button (2) to change the power to partial or full load.
At full heating capacity, “HI” is shown in the display (5) and half heating capacity (4) shows
"LO" is deactivated.
In the case of partial capacity heating, "LO" is activated on the display (4) and "HI" is
deactivated on the display (5).
Manual Mode and Auto Mode
Press the “M/A” mode selection button (19) to change the mode to Manual or Auto.
In manual mode, the display (7) shows an "M" while the "A" is hidden on the display.
In auto mode, the display (8) shows an "A" and the "M" is hidden on the display.
Shutdown Memory Function
Press the power switch (20) to turn the unit off and on again. When the unit is switched
back on the temperature default is the last set and the previously scheduled timers are
still activated.
Both the Auto Mode Timer and the Manual Mode Timer have a shutdown memory
function
Switching off the Electrical Memory Function
If the unit is unexpectedly turned off or there is a sudden power failure, only the power
indicator (1) lights up when the power is back on and the system is in standby.
Press the power button (20) to turn the system back on. The system operates in the last
mode in use before the power outage.
Delete Timers
Hold the "OK" button (12) for 5 seconds until a "di" tone is sounded, all prior daily and
weekly timers will now be erased.