Table for information requirements for electric local space heaters
P
DVPH1200B/
DVPH12BEP
DVPH2000B/
DVPH20BEP
DVPH2400B/
DVPH24BEP
Item
Symbol
Value
Unit
Heat output
Nominal heat output
Pnom
1.2
2.0
2.4
kW
Minimum heat output (indicative)
Pmin
0.12
0.20
0.24
kW
Maximum continuous heat output
Pmax
1.15
1.97
2.36
kW
Auxiliary electricity consumption
At nominal heat output
elmax
1.150
1.978
2.368
kW
At minimum heat output
elmin
0.123
0.192
0.235
kW
In standby mode
elSB
0.0003
0.0003
0.0003
kW
Item
Type of heat input, for electric local space heaters only (select one)
[no]
Manual heat charge control with integrated thermostat
[no]
Manual heat charge control with room and/or outdoor temperature feedback
[no]
Electronic heat charge control with room and/or outdoor temperature feedback
[no]
Fan assisted heat output
[no]
Type of heat output/room temperature control (select one)
Single stage heat output and no room temperature control
[no]
Two or more manual stages, no room temperature control
[no]
With mechanic thermostat room temperature control
[no]
With electronic room temperature control
[no]
Electronic room temperature control plus day timer
[yes]
Electronic room temperature control plus week timer
[no]
Other control options (multiple selections possible)
Room temperature control, with presence detection
[no]
Room temperature control, with open window detection
[yes]
With distance control option
[yes]
With adaptive start control
[no]
With working time limitation
[no]
With black bulb sensor
[yes]
Contact details:
Remark:
For electric local space heaters, the measured seasonal space heating energy efficiency ηs cannot
be worse than the declared value at the nominal heat output of the unit.