E / H KIT INSTALLATION INSTRUCTIONS
1) Attach adapters to E/H valve and install inside cavity on headache rack.
2) Attach return hose to valve and filter housing. Attach pressure hose from pump.
3) Attach blue and yellow wires from hand control to valve cartridge that controls
squeeze cylinder as indicated.
4) Attach green and brown wires from hand control to valve cartridge that controls
lift cylinder as indicated.
5) Attach ground harness to valve coils with similar color wires (yellow, brown and
green). Blue and red wires are on same coil.
6) Attach 1/2” hoses from squeeze cylinder to side of valve controlled by blue and
yellow wires. If hand control does not respond as desired, pioneer couples on
rear of bed may be reversed or blue and yellow wires may be reversed.
7) Attach 3/8” hoses from lift cylinder side of valve controlled by green and brown
wires. If hand control does not respond as desired, green and brown wires may
be reversed.